Applications · Small animal breeding
Climatic chambers for small animal breeding
Temperature, humidity, light and air under control to breed small mammals, birds, amphibians and invertebrates for research, with animal welfare and biosafety as the starting point.
What small animal breeding needs
Research animals need a stable environment: changes in temperature, humidity or light alter their physiology and behaviour, and with them the results of a study.
A breeding chamber holds those conditions day and night and adds what working with animals requires: flicker-free light that respects the circadian rhythm, filtered air renewal, easy-to-clean surfaces and alarms that warn before anything goes wrong. It is used in disease research, toxicology, pest control, genetics and species conservation.
Temperature
Stable and free of gradients. Each species has its range: laboratory rodents are housed at 20 to 24 °C.
Humidity
Optional ultrasonic humidity control, 30 to 80 % RH, for species that need it.
Light
Flicker-free LED up to 6,000 lux, with a programmable photoperiod for day and night.
Air
Fresh air renewal, CO2 control and HEPA and activated carbon filters for a clean atmosphere.
Typical housing conditions
| Group | Temperature | Humidity | Photoperiod |
|---|---|---|---|
| Mice, rats, hamsters and gerbils | 20-24 °C | 45-65 % RH | 12 h light / 12 h dark, typical |
| Amphibians (Xenopus) | 18-22 °C in the water | High | 12 h / 12 h, typical |
| Reptiles | 24-32 °C, depending on the species | Depending on the species | Depending on the species |
| Invertebrates (C. elegans and others) | 15-25 °C | Depending on the test | Depending on the test |
Indicative values. Those for rodents and Xenopus follow Annex III of Directive 2010/63/EU on animals used for scientific purposes. Each facility also applies its own procedures.
Recommended chambers

EcoLine
ERIS ZOO INOX
- 3 sizes: 455, 855 and 1,345 L
- ±0.3 °C stability at +27 °C
- Flicker-free LED up to 6,000 lux
- Fresh air, CO2 and HEPA and activated carbon filters
Choose it if… you breed mammals, birds or amphibians and need a stable, clean and monitored environment.

EcoLine
ERIS DPH INOX
- 5 sizes, from 150 to 1,345 L
- +10 to +55 °C; versions down to -20 °C
- Flicker-free 2800 K LED
- External humidifier and protective mesh
Choose it if… you work with invertebrates or insects and need humidity without heat and escape protection.

WalkInLine
Walk-in chamber
- 6 to 50 m³, built to measure
- Room for trolleys and racks
- Programmable climate, light and air
- Trapped-person alarm
Choose it if… you house many cages or need a whole climate-controlled room.
Options designed for breeding
Inner glass door
Lets you watch the animals without changing the temperature or humidity.
Fresh air and CO2
Automatic ventilation dampers and CO2 control to suit the species.
HEPA and activated carbon filters
For settings with high biosafety requirements and odour control.
Backup battery
Keeps control running for 48-72 hours during a power cut.
Remote monitoring
7″ touch screen with Ethernet and EQUITEC FITOCONTROL software, with email or SMS alerts.
Stainless steel interior
AISI 304 with drain and removable shelves up to 100 kg/m², easy to clean.
How to choose your breeding chamber
- Species and cages. Count the cages or terraria you will house at once and leave room for air to flow.
- Climate. Set the temperature range and decide whether you need humidity control.
- Light. Program the photoperiod for the species and the study.
- Biosafety and monitoring. Decide which filters, alarms and power backup your facility needs.
Frequently asked questions
What temperature and humidity do mice and rats need?
Annex III of Directive 2010/63/EU recommends 20 to 24 °C and 55 % ± 10 % humidity. ERIS ZOO INOX holds temperature with ±0.3 °C stability at +27 °C and can include humidity control from 30 to 80 % RH.
Can the light cycle be programmed?
Yes. The flicker-free LED reaches 6,000 lux and the controller programs the photoperiod in segments, together with temperature, humidity and ventilation.
How is the air renewed?
With automatic ventilation dampers for fresh air, CO2 control and optional HEPA and activated carbon filters.
What happens during a power cut?
With the optional backup battery, the chamber keeps control for 48 to 72 hours. Alarms are logged and, with FITOCONTROL, sent by email or SMS.
Can I see the animals without opening the chamber?
Yes, through the inner glass door: you can watch the animals without letting room air in or changing the conditions.
Technical advice
Let’s talk about your animals
Tell us which species you house, how many cages you need and what your protocol requires. We will recommend the right configuration and send you the catalogue and a quote.
- Model and option recommendation
- Full series catalogue
- Quote tailored to your facility