Applications · Laboratory incubation
Laboratory incubation for BOD, microbiology and sample storage
Cooled incubators that hold the exact test temperature, below or above that of the lab, with even airflow on every shelf and recorded data.
What incubation needs
Incubating means keeping a sample at a set temperature for hours or days. If the temperature drifts or differs between shelves, the final count or reading is no longer comparable.
That is why water, food, pharmaceutical and microbiology labs use incubators with refrigeration and forced air circulation. A heat-only incubator cannot go below room temperature; a cooled one holds the 20 °C of BOD or the 25 °C of yeasts and moulds even when the lab reaches 28 °C in summer.
Exact temperature
±0.3 °C stability at +27 °C and PID control, for tests with ±1 °C tolerances.
Uniformity
Horizontal airflow at the height of each shelf, so every sample sees the same conditions.
Cooling and heating
Natural R-290 refrigeration: the same unit incubates below and above room temperature.
Traceability
Alarms, password protection and data logging with USB download or network connection, depending on the model.
Typical incubation conditions
| Test | Temperature | Time | Notes |
|---|---|---|---|
| BOD5 (biochemical oxygen demand) | 20 ± 1 °C | 5 days | In the dark |
| Microorganism count at 30 °C (ISO 4833-1) | 30 ± 1 °C | 72 h | Plates on wire or perforated shelves |
| Yeasts and moulds (ISO 21527) | 25 ± 1 °C | 5 days | Plates upright |
| Psychrotrophic microorganisms (ISO 17410) | 6.5 ± 1 °C | 10 days | Needs an incubator that goes below +10 °C |
| Cultures at 37 °C | 37 ± 1 °C | 24-48 h | If the room is cooler, an incubation oven is enough |
Values taken from the methods cited, for guidance. Each lab applies the version of the standard and the procedures it is accredited for.
Recommended chambers

EasyLine
ERI EasyLine
- 5 volumes, from 150 to 1,345 L
- +10 to +55 °C; larger models go down to +4, 0 or -10 °C
- Stainless steel interior
- Optional 30 to 80 % humidity and LED
Choose it if… you need a multipurpose cooled incubator for microbiology, food or pharma.

EasyLine
ERI DBO
- 6 volumes, from 60 to 1,250 L
- +10 to +55 °C; models 600 to 1250 go down to -5 °C
- Internal sockets as standard
- Same airflow for every bottle
Choose it if… BOD5 is your main test or you run shakers inside the incubator.

EasyLine
EICR
- 3 volumes: 150, 250 and 400 L
- 0 to +70 °C; the 250 and 400 go down to -10 °C
- Optional Nanodac controller and WiFi module
- Optional humidity and LED
Choose it if… you need to incubate close to 0 °C or up to +70 °C in a compact unit.
Options for every test
Internal sockets
For shakers, BOD heads or other equipment during incubation. Standard on ERI DBO.
Humidity control
Ultrasonic humidifier that adds no heat, for samples that must not dry out.
LED lighting
4000 K light with day/night photoperiod by timer. BOD is run with the light off.
Data logging
Series 4500 touch screen, Nanodac controller or paper chart recorder, depending on the model.
Range below +10 °C
Versions down to +4, 0, -5 or -10 °C for psychrotrophs and sample storage.
Inner glass door
To see the samples without losing temperature when opening.
How to choose your incubator
- Test and room temperature. If the room can exceed the incubation temperature, choose a cooled incubator.
- Capacity. Count bottles, plates or racks at a time and add replicates and blanks.
- Humidity, light and cold. If you need them, start with the models that support them: ERI 452, ERI DBO 600 or EICR 250.
- Traceability. For accredited labs, add data logging and remote alarms.
Frequently asked questions
Why a cooled incubator if I incubate above room temperature?
Because the room is not always cooler than the test. In summer, or next to other equipment, a lab easily exceeds 25 °C. A heat-only incubator cannot go below that; a cooled one holds the set point whatever happens in the room.
At what temperature is BOD5 incubated?
In the most common method, at 20 ± 1 °C for 5 days in the dark. ERI DBO works from +10 to +55 °C, with internal sockets as standard for stirred BOD heads.
What is the difference between ERI EasyLine, ERI DBO and EICR?
ERI EasyLine is the multipurpose incubator with a stainless interior, from 150 to 1,345 L. ERI DBO is designed for BOD, starts at 60 L and has internal sockets as standard. EICR is the most compact and has the widest range: 0 to +70 °C in 150, 250 or 400 L.
Can I put shakers inside?
Yes. ERI DBO has internal sockets as standard, and they are optional on ERI and EICR. For chromatographs or large shakers there is the ERIS CROM cooled incubator.
What if I only need to incubate at 37 °C?
If the room is always below that temperature, an incubation oven that heats up to +80 °C is enough. If the room can get close to the test temperature, a cooled incubator is the better choice.
Technical advice
Let’s talk about your tests
Tell us what you incubate, at what temperature and how many samples at a time. We will recommend the right model and send you the catalogue and a quote.
- Model and option recommendation
- Full series catalogue
- Quote tailored to your lab