What a plant needs in a growth chamber

Away from the greenhouse, a plant only gets what the chamber gives it: light, day and night temperature and humidity. When those conditions are stable and programmable, tests repeat the same way at any time of year.

These chambers are also called phytotrons. They are used in plant physiology, breeding, seed germination and vigour testing, phenotyping, photoperiod and vernalisation studies, and producing high-quality plants for research.

Light

LED with up to 8 channels, from ultraviolet to far red, with programmable intensity and photoperiod.

Temperature

Day/night cycles and alternations. Versions below +10 °C for cold treatments and vernalisation.

Humidity

Ultrasonic humidifier that adds no heat, for germination and sensitive seedlings.

Uniformity

Airflow at shelf level, so every tray grows the same way.

Typical growing conditions

ApplicationTemperatureLightOther
Arabidopsis thaliana20-22 °C100-150 µmol/m²/s, 16 h long day60-70 % RH
Seed germination tests20 °C constant or 20-30 °C alternatingDepending on the species, often 8 h of lightMoist substrate, not waterlogged
Vernalisation and cold acclimation+4 to +5 °CLow light, short daySeveral weeks
Tall plants (tomato, cereals)18-28 °C, day/night cycle400-1,000 µmol/m²/sOptional CO2

Indicative values from common protocols. Every species, test and lab has its own requirements: we help you configure the chamber for yours.

Recommended chambers

ERIS INOX LED

EcoLine

ERIS INOX LED

  • 5 sizes, from 150 to 1,345 L
  • +10 to +55 °C; versions down to -20 °C
  • LED at 220 µmol/m²/s as standard, up to 450
  • Light on the door, sides or each shelf

Choose it if… you want a practical growth chamber for germination, seedlings and small plants.

ERIS INOX LED product pageSeries catalogue

EGCS

ProLine

EGCS

  • 18 volumes, from 190 to 3,500 L
  • +4 to +60 °C; options from -30 to +80 °C
  • Humidity 30 to 90 %, extendable to 10-95 %
  • LED up to 1,000 µmol/m²/s and 8 channels

Choose it if… you work with tall plants, high light or extreme ranges.

EGCS product pageSeries catalogue

EGC WK

WalkInLine

EGC WK walk-in

  • 6 to 50 m³, built to measure
  • Up to 31.68 m² of growing area on several levels
  • LED from 300 to 1,500 µmol/m²/s, up to 3,000
  • Optional irrigation, hydroponics and CO2

Choose it if… you need a large growing area, trolleys or benches.

EGC WK product pageSeries catalogue

Options for plant growth

Multi-channel LED

1, 3, 4 or 8 separately dimmable channels, from ultraviolet to far red, 2700 to 7000 K.

Light position

On the door (1S), the sides (2S), both (3S) or on each shelf (1L to 4L).

Humidity control

30 to 80 % RH on ERIS, extendable up to 95 % or down to 20 %.

CO2

Monitoring, set-point injection with an NDIR sensor or air renewal.

Light sensors

PAR radiation sensor and PPFD and spectrum meters.

Remote control

EQUITEC FITOCONTROL software to monitor every chamber from a PC or phone.

How to choose your growth chamber

  1. Plant height. Tall plants: light on the door and sides. Seedlings, plates or in vitro: light on each shelf.
  2. Growing area. Count the trays or plates at a time and choose the volume and shelves from there.
  3. Light. Intensity and channels depend on the test. Spectrum studies need 4 or 8 channels.
  4. Temperature. For cold treatments or vernalisation, ask for the version below +10 °C from the start.

Frequently asked questions

What is a phytotron?

It is a growth chamber that controls temperature, humidity and light so plants grow under defined, repeatable conditions. The name comes from the first labs of this kind, built in the mid-20th century.

How much light do plants need in a growth chamber?

It depends on the crop. Arabidopsis and seedlings grow well at 100-150 µmol/m²/s; tall plants such as tomato or cereals need 400 µmol/m²/s or more. ERIS INOX LED reaches 450, EGCS 1,000 and EGC WK up to 3,000 µmol/m²/s.

Can I run germination tests with alternating temperatures?

Yes. The controller programs temperature, humidity and light in segments, so you can alternate, for example, 8 hours at 30 °C with light and 16 hours at 20 °C in the dark.

Can I vernalise in the chamber?

Yes, with the extended-range versions. ERIS INOX LED goes down to -20 °C and EGCS to -30 °C, so they can hold the usual +4 °C of vernalisation for weeks.

What is the difference between ERIS INOX LED and EGCS?

ERIS INOX LED covers standard applications in 5 sizes, +10 to +55 °C as standard. EGCS is the high-end range: 18 volumes, -30 to +80 °C, 10 to 95 % humidity, two airflow layouts and LED up to 1,000 µmol/m²/s.

Technical advice

Let’s talk about your plants

Tell us which species you grow, in what format and which light and climate conditions you need. We will recommend the right configuration and send you the catalogue and a quote.

  • Model and lighting recommendation
  • Full series catalogue
  • Quote tailored to your test

Data protection. Controller: Testing Lab Equipments, S.L. Purpose: to answer your enquiry or request. Legal basis: pre-contractual steps taken at your request. Recipients: authorised TestingLab distributors when needed to serve you; we do not disclose your data for any other purpose. Rights: access, rectification, erasure and others, at contact@testinglab.es. More information in our Privacy policy.